Ремонт VW TCU Multitronic VL300

Ремонт VW TCU Multitronic VL300

Типичные проблемы

- нет связи с модулем

Код ошибки

17089 / P0705 Transm.Range Sensor Circ.(PRNDL Inp.) Malfunction
17090 / P0706 Transm.Range Sensor Circ Range/Performance
17091 / P0707 Transm.Range Sensor Circ Low Input
17092 / P0708 Transm.Range Sensor Circ High Input
17099 / P0715 Input Turbine/Speed Sensor Circ. Malfunction
17100 / P0716 Input Turbine/Speed Sensor Circ. Range/Performance
17101 / P0717 Input Turbine/Speed Sensor Circ. No Signal
17105 / P0721 Output Speed Sensor Circ Range/Performance
17106 / P0722 Output Speed Sensor Circ No Signal
17991 / P1583 Transmission mount valves Short to B+
18243 / P1835 Pressure Contr.Solenoid 5 Short to B+
17992 / P1584 Transmission mount valves Short to ground
17993 / P1585 Transmission mount valves Open circuit
18206 / P1798 Output Speed Sensor 2 Circ. Range/Performance    
18207 / P1799 Output Speed Sensor 2 Circ. Rpm too High
18221 / P1813 Pressure Contr.Solenoid 1 Electrical
18222 / P1814 Pressure Contr.Solenoid 1 Open/Short to Ground
18223 / P1815 Pressure Contr.Solenoid 1 Short to B+
18226 / P1818 Pressure Contr.Solenoid 2 Electrical
18227 / P1819 Pressure Contr.Solenoid 2 Open/Short to Ground
18228 / P1820 Pressure Contr.Solenoid 2 Short to B+
18231 / P1823 Pressure Contr.Solenoid 3 Electrical
18232 / P1824 Pressure Contr.Solenoid 3 Open/Short to Ground
18233 / P1825 Pressure Contr.Solenoid 3 Short to B+
18236 / P1828 Pressure Contr.Solenoid 4 Electrical
18237 / P1829 Pressure Contr.Solenoid 4 Open/Short to Ground
18238 / P1830 Pressure Contr.Solenoid 4 Short to B+
18242 / P1834 Pressure Contr.Solenoid 5 Open/Short to Ground

Гарантия 6 месяцев

Полгода, без ограничения пробега
Гарантия покрывает стоимость доставки

Ask your question